These settings control the device hardware and how a transaction can start:- Decimal Place: defines the Nayax device and affects the Default Credit value.
This is usually
2. - Transaction Start Method: set to Accept Nothing. This defines what can start a transaction through the card reader while it is idle. For Remote Start, the server calls the card reader, so no physical action is needed and physical starts are blocked.

If you use Device Stop on this machine, the Transaction Start Method is set
differently. Follow Device Stop Configuration.
Communication
This setting defines how the Nayax device communicates with the Nayax servers:- Communication Mode: set to MQTT Enabled. For Remote Start, the server has to wake the device, so the device must listen for requests coming from the server. The MQTT protocol supports this. The alternative is VPN Enabled, which needs a SIM card that supports the protocol.
- MQTT - Primary Address: contact your Nayax Support representative for the address that fits your device location.

MDB
The MDB Flags setting tells the server which payment flow the device supports:- Pre-Authorization is used when the transaction starts before the consumer chooses a product or service and before the final amount is known. Set MDB Flags to * Flags Disabled.
- Pre-Selection is the flow used when the price is known when the card is presented. Set MDB Flags to 02 PreSelection Enabled.

Payment
These settings control the authorization amount and how long the device waits for a card:- Default Credit: set the authorization amount. This applies to the
Pre-Authorization flow only. It is the amount authorized when the
Amountfield in theTriggerTransactionrequest is empty. The value is in cents and is affected by the Decimal Place value. The settlement value cannot be higher than this amount. - Present Card Timeout: the time in seconds the device waits for a card after the server wakes it. The default is 15 seconds. We recommend 30 to 60 seconds so consumers have enough time to reach the terminal and present their card.
Pulse/ccTalk
These settings define the credit applied per pulse:- Credit per Pulse 1: set to
1. - Number of Pulses per Vend 1: set to
1.
VPOS Touch
The VAS configurations setting is optional for Remote Start. You can add an indication that the machine performs Spark Remote Start. This is not required for the flow to work and is only for management purposes.Spark Remote Start and Spark Device Start cannot coexist on the same machine.
Configuration Summary
Use the following table as a quick reference for the Remote Start settings:Next Steps
Remote Start
See how the Remote Start transaction flow works at the API level.